Re: Continuous sampling using AD7656 evaluation software
Hi Jonathan,I've checked the device manager and it shows as following. ADI Development Tools Analog Devices System Demonstration Platform SDP-B So I think it's been installed correctly. I tried to...
View ArticleRe: phase locked loop IC
Hi, Moki. I moved your question about PLL in RF Community. Someone here should be able to assist you. While waiting for the PLL experts, you may look at this link - PLL / PLLs with Integrated VCOs |...
View Articlerequest for information on SDP-H1
Hi, I was looking for suitable hardware for my application in AD's website and I saw the SDP-H1. In my application, I need to acquire data using ADC, 16 bit with minimum sampling rate of 4MSps. I also...
View ArticleRe: SigmaDSP programming
Hello, There's no C compiler for any SigmaDSP. Among other reasons, this is because these are primarily streaming audio processors for which not every C construct can be implemented. For...
View Articlecomposite amplifier
I am sampath Bandara I need to construct composite amplifier so my desire gain is 45 and total bandwidth of 50 MHz with low noise and low offset voltage, high slew-rate. I highly appreciate if you can...
View ArticleRe: Sigmastudio algorithms
Hello Graeme, It sure seems like this block, Timer Coarse Long Time, is MIA. It doesn't show up in any SigmaStudio version I tried, from 3.10.4 to the latest beta. Best regards, Bob
View ArticleRe: About AD5700 Carrier Detect Off Timing
Hi David, Thank you for reply.I think so,HART SIGNALdoesnot knowthe MCUside.Therefore,you will not be ableto interpret thet5.Intable.5,do youhave timeprovisions ofthe falling edge of theCD from...
View ArticleRe: AD9361 About the results of the calibration.
Hi tlili. Is itmay beconsidered that there is noquadraturecalibrationcompletion statusregisterofRx? Best Regards.Hara
View ArticleRe: AD9361, AGC with LTE10 MHz configuration
Input signal is @752 MHz (carrier frequency = 751 MHz)Input level = -30 dBmEach time I read 0x1A7 it's changing but for example, I read back some value - -49 dBm, -74 dBm, --84 dBm, -78 dBm ... I...
View ArticleRe: Interfacing AD9633 eval board with ML605 using an ADI working reference...
Hi z00345up, Thank you for considering the AD9633. Indeed as you have discovered, the AD9633 is not one of the devices that is compatible with the FMC interposer (CVT-ADC-FMC-INTPZB) as-is. The problem...
View ArticleSigmaStudio Automatic Speaker EQ Usage
HiI would like to use Auto-EQ by ADAU1761 or ADAU1701 , I try to add this algorithm in DSP schematic sheet and open this algorithm. The Auto-EQ have to set a source response and it might need to load...
View ArticleBF60x, driver type for USB0_VBC
Hi, Could you please provide quick answer for what is Driver Type="E" at BF60x USB0_VBC pin which is described in BF60x datasheet Rev.A, Table 15. ADSP-BF60x Designer Quick Reference at page.51 ?It...
View ArticleADI Sigmastudio question
Dear Sir,In Sigmastudio,Schematic==>Tree Tool Box ==>IO==>GPIO==>Output==>Interface WriteWhat's the Interface Write function?ADAU1761 can use Interface Write? Thanks.
View ArticleADF4155 ref input
Is it acceptable to feed the ref input to the ADF4155 with a single ended source? I assume I can just AC couple to ground the ref- pin? Any tradeoffs with doing this vs. using a true differential input?
View ArticleRe: composite amplifier
Hi Sampath, I suggest you can use the AD8651/AD8652 part. AD8651/AD8652 has a bandwidth of 50 MHz at 5V supply, has low noise density of 4.5 nV/√Hz at 100 kHz, has a typical offset voltage of 100 uV...
View ArticleRe: AD7903 calculate LSB
Hi Dirk, I think you computed the LSB right. LSB should be 152.6uV. The AD7903 datasheet will be updated to reflect the correct one. Regards,Jonathan
View ArticleRe: AD7626 recovering from power-down
Hi Shackleton, The 9.5 sec wake up time is correct for the AD7626. As mentioned on the datasheet, this is the wake up time for when AD7626 uses the internal reference and internal reference...
View ArticleThe settling time of switching from CDS mode to SHA mode.
Hello, My friend is trying to use AD9982 with CIS.He has a question about the settling time of switching from CDS mode to SHA mode.When using CIS he connects the vref level of CIS module to the OFFSET...
View ArticleRe: Capturing data fail using AD9625 EVB and ADC-EVALEZ
Hi Ian, Thank you for responding so quickly.I downloaded the two softwares from analog.com last week, the version numbers are: Visual Analog: 1.9.45.52SPI Controller: 4.0.7.4062 The driver located...
View ArticleRe: ADC to KC705 board
Hi Kevin, I moved the discussion to the high speed ADC community. Someone here will be able to help you in your inquiry. Regards,Jonathan
View Article